Innovative heat-resistant cable with temperature index 260 °С 



Technical characteristics

  • Conductor area, mm2

    10-25

  • Working voltage, kW

    4

  • Operating temperature limit, °С
    260

  • Hydrogen sulfide content, g/l
    up to 1,25

  • Gas-oil ratio, m3/m3

    up to 500

  • Hydrostatic pressure, kg/sm2
    400


Design features

  • Stainless Steel armor

  • Smaller dimensions

  • Lower weight

  • Mechanical damage-resistant insulation

  • Using innovative high temperature polymeric material in insulation


Heat-resistant cable for submersible pumps with temperature index 130 °С



Technical characteristics

  • Conductor area, mm2

    10-25

  • Working voltage, kW

    3,3

  • Operating temperature limit, °С
    130

  • Hydrogen sulfide content, g/l
    up to 1,25

  • Gas-oil ratio, m3/m3

    up to 30

  • Hydrostatic pressure, kg/sm2
    350


Design features

  • Stainless Steel armor

  • No contact between polypropylene block copolymer and a copper conductor

  • Using of film insulation thermal class С


Heat-resistant cable for submersuble pumps with temperature index 160 °С 



Technical characteristics

  • Conductor area, mm2

    10-25

  • Working voltage, kW

    3,3

  • Operating temperature limit, °С
    160

  • Hydrogen sulfide content, g/l
    up to 1,25

  • Gas-oil ratio, m3/m3

    up to 500

  • Hydrostatic pressure, kg/sm2
    400


Design features

  • Stainless Steel armor

  • Smaller dimensions

  • Lower weight

  • Using innovative high temperature polymeric material in insulation


Power cables and MLE for submursable pumps



Technical characteristics

  • Conductor area, mm2

    10-25

  • Working voltage, kW

    4

  • Operating temperature limit, °С
    130-260

  • Hydrogen sulfide content, g/l
    up to 1,25

  • Gas-oil ratio, m3m3

    up to 500

  • Hydrostatic pressure, kg/sm2
    400


Design features

  • Stainless Steel armor

  • Smaller dimensions

  • Lower weight

  • Couplings for domestic and imported motors

  • Condutors are mechanically fixed in a coupling


Heat-resistant windings with film-on polyimide-fluoroplastic insulation



Technical characteristics

  • Diameter, mm

    1,5-3,0

  • Breakdown voltage, kW
    18-22

  • Operating temperature limit, °С
    200

  • Insulation impedance, Mohm
    2000

  • Peak voltage, kW

    8

  • Length, m

    700-1000


Design features

  • Using films Kapton, Apical

  • Improved mechanical properties

  • Using high-grade copper


Heat-resistant restangular windigns



Technical characteristics

  • Breakdown voltage, kW
    more 6

  • Operating temperature, °С
    -60... +200

  • Length, m
    more 150


Design features

  • Using films Kapton, Apical

  • Improved mechanical properties

  • High-quality copper


Electric copper round wire


Technical characteristics

  • Diameter, mm
    1,5-6,0

  • Specific electric resistance, Ohm.mm2/ m
    max 0.01724 x 106

  • Elongation at break, %
    more 30



Copper profile for submersible electric motor rotors


Technical characteristics

  • Hardness, НВ
    max 110

  • Specific electric resistance, Оhm.mm2/m
    max 0,01724 х 106